Accessories Quote
"*" indicates required fields
The RS 1800·Q Biological Irradiator is a cutting-edge research tool designed to provide precise and reliable irradiation for a wide range of life science applications. With its advanced features and user-friendly interface, the RS 1800·Q is an ideal solution for researchers seeking to advance their work in fields such as cancer research, immunology, and gene therapy.
When paired with RadPlus tools, the RS 1800·Q offers enhanced functionality and streamlined workflows, allowing researchers to focus on their science rather than the technology. Flexibility and precision make it an essential instrument for any research laboratory, and its compact design ensures it can be easily integrated into even the most space-constrained facilities.
The RS 1800·Q Biological Irradiator leverages the power of QUASTAR technology to deliver unparalleled levels of precision and uniformity in radiation dose delivery. This advanced technology produces a larger, stronger, and higher-energy photon field, ensuring that even the most sensitive samples receive a consistent and reliable dose.
By harnessing the advantages of QUASTAR technology, the RS 1800·Q sets a new standard for irradiation research, enabling scientists to achieve more accurate and reproducible results in a wide range of life science applications:
Key Features and Advantages
The RS 1800·Q Biological Irradiator stands at the forefront of cell research technology, offering unparalleled precision and flexibility for tissue and cell irradiation. Designed specifically for life sciences, it integrates Rad Source’s patented QUASTAR® x-ray technology and RADPlus™ solutions to ensure superior dose uniformity and optimal configuration for various research applications.
High X-Ray Output for High Throughput
Achieve significant throughput with a large radiation field that does not require collimation, ensuring efficient operation and high dose rates perfect for demanding research environments.
Enhanced Uniformity and Dosage Control
Our patented RADPlus™ technology provides up to 95% dose uniformity, enhancing the reliability of your experimental results. This technology is critical for applications requiring consistent radiation exposure, such as cancer cell studies, immunology, and stem cell research.
Advanced Portability and Flexibility
The RS 1800·Q is mounted on sturdy caster wheels, promoting easy relocation within your facility to suit different study setups and enhance workflow efficiency.
Direct Replacement for Gamma Irradiators
Recognized by the U.S. FDA as a substantially equivalent and safer alternative to traditional radioactive sources, the RS 1800·Q eliminates the need for nuclear regulatory compliance, simplifying your operations and reducing long-term costs.
Self-Contained, Safe, and Secure
Built to meet stringent safety standards (21 CFR 1020.40), our self-contained cabinet design requires no additional security measures, allowing you to focus on research without safety concerns.
Specialized for Diverse Research Needs
Multi-level Exposure System: Features a three-level exposure chamber with adjustable shelves and concentric circle guides, enhancing flexibility in sample placement and irradiation accuracy.
Software & Human Interface Integration: Equipped with an intuitive touchpad, programmable controls, and comprehensive data recording capabilities, all accessible remotely for streamlined operation and data management.
Dedicated Support and Proven Reliability
With over two decades of service in the life science sector, Rad Source is committed to excellence with a global network of support. Our systems, including the RS 1800 Q, are backed by extensive research, innovation, and a commitment to improving life science research outcomes worldwide.
Equipment Dimensions (W x D x H)
30 x 36 x 64″ | 76.2 x 91.44 x 162.56 cm
Internal Chamber Dimensions (W x D x H)
11 x 14 x 13.25″ | 27.94 x 35.56 x 33.66 cm
Clearance Dimensions (W x D x H)
35 x 40 x 71″ | 88.90 x 101.60 x 180.34 cm
Equipment Weight
1350 lbs. | 612.35 kg
Power
RS 1800 Q – 2000W
RS 1800 Q4 – 4000W
Electrical
Power: 208/240VAC, Single phase, 50/60Hz, 30 Amp, true earth ground. Wiring: 10 AWG L1, L2/N
Dose Rate (Gy/min)
RS 1800 Q
Shelf: 4-100 Gy/min | Flatness: 75%
50mL Falcon RADPlus: 5 Gy/min | Flatness: 97%
Petri Dish RADPlus: 5Gy/min | Flatness: 85%
Well-Plate RADPlus: 5-20 Gy/min | Flatness 90% – 50%
RS 1800 Q4
Shelf: 8-200 Gy/min | Flatness: 75%
50mL Falcon RADPlus: 6.5 Gy/min | Flatness: 97%
Petri Dish RADPlus: 5 Gy/min | Flatness: 85%
Well-Plate RADPlus: 5-20 Gy/min | Flatness 90% – 50%
INSTALLATION:
For the installation, the unit will arrive at your facility in the morning and will be met by our install team. All irradiators receive a quality inspection, dose map, and radiation survey prior to shipment and again at installation. On-site Training Included at installation.
Water Requirements:
3 gallons of distilled water for the irradiator’s internal water tank.
Cooling Requirements:
Not Required
WARRANTY INFORMATION
Ionizing radiation comes from radioactive sources such as cobalt 60 and cesium 137 and non-radioactive sources such as X-ray tubes. Radioactive sources are unstable materials where gamma rays originate from the nucleus. X-rays originate in the electron fields surrounding the nucleus or are machine-produced.
Because of the penetrating properties of ionizing radiation and their ability to kill microorganisms, ionizing radiation is used to sterilize or reduce the microbial load of many different types of products such as medical devices, packaging, cosmetics, foods, and agricultural products. It is also used to alter the properties of many different polymers through recombination, cross-linkage, and cross scission.
Features:
○ Durable and lightweight aluminum construction for easy handling.
○ Can be placed on the floor or either of the two chamber shelves, offering dose rate flexibility.
○ Compatible with placing well plates and petri dishes directly on its surface.
○ Dimensions: 10.76″ x 13.36″ x 0.125″.
Benefits:
○ Provides a versatile platform for various sample sizes and containers.
○ Allows researchers to adjust dose rates based on shelf placement
Features:
○ Made with proprietary RADPlus material for uniform dosing and higher dose rates.
○ Can accommodate well plates, petri dishes, and other lab components placed directly on the shelf.
○ Features corner markings to align the Well Plate Holder precisely.
○ Dimensions: 10.75″ x 13.4″ x 1.5″.
Benefits:
○ Offers higher dose rates compared to the Aluminum Shelf, while maintaining uniformity.
○ Provides flexibility in sample placement and compatibility with multiple container types.
Features:
Features:
○ Compatible with standard 24- and 96-well plates.
○ Can be used on the Aluminum Shelf, RADPlus Shelf, or the floor of the chamber at levels 1 or 2.
○ Features corner markings for precise placement on the shelves.
○ Dimensions: 8″ x 6″ x 1.75″.
Benefits:
○ Provides dose rate flexibility depending on its placement within the chamber.
○ Using the RADPlus Shelf yields higher dose rates than the Aluminum Shelf, maintaining comparable dose uniformity
Features:
○ Accommodates three standard-size (100 mm x 15 mm) petri dishes or up to fourteen smaller-sized petri dishes.
○ Dimensions: 10″ x 10″ x 1.75″.
Benefits:
○ Enables simultaneous irradiation of multiple petri dish samples.
Medulloblastoma is a highly invasive cancer of central nervous system diagnosed mainly in children. Matrix metalloproteinase-9 (MMP-9) and urokinase plasminogen activator receptor (uPAR) are over expressed in several cancers and...
Combined treatment with thioridazine and irradiation significantly reduced viability of ESCC cells compared with thioridazine or irradiation treatment alone. Thioridazine and irradiation treatment induced G0/G1 phases cell cycle...
Abstract: Nanoparticle thermotherapy (NPTT) uses monoclonal antibody-linked iron oxide magnetic nanoparticles (bioprobes) for the tumor-specific thermotherapy of cancer by hysteretic heating of the magnetic component of the...